007 Plus (Burnout oven) / ES71 (Catalyst Cleaner)
Burnout Furnace
Troubleshooting
007 Plus Error 6 Thermocouple Replacement and Platinum Catalyst Filter Replacement Troubleshooting
Order Parts Item Code & Name
Mechanical Support
2 – Stages Program
Suppose you store a firing program on Program Course 1 as follows.
- L Rise: 6°C/min
- L Temp: 300°C
- L Hold: 10 min
- M Rise: 11°C/min
- M Temp: 900°C
- M Hold: 1h 20 min
- Chime volume: High (2)
- Turn the power on and press [▲▼] to set 1 on the program course and press [PRG.]
- Press [▲▼] to set 6 °C/min and press [OK/PASS]
- Press [▲▼] to set 300 °C/min and press [OK/PASS]
- Press [▲▼] to set 0.20 hour and press [OK/PASS]
- M Rise, M Temp, and M Hold are programmable in the same way as done in above
- You have M Chime lamp being illuminated but at this process press [OK/PASS]
- In the 2-STAGE PROGRAM, H process is not use so press [▲▼] to set PASS and press [OK/PASS]
- Press [▲▼]to display on -2
- Press [PRG.]
3 – STAGES PROGRAM
Suppose you store a firing program on Program Course 2 as follows.
- L Rise: 6°C/min
- L Temp: 300°C
- L Hold: 10 min
- M Rise: 11°C/min
- M Temp: 700°C
- M Hold: 5 min
- M Chime: Low (1)
- H Rise: 8°C/min
- H Temp: 900°C
- H Hold: 1 hour 20min
- Chime volume: High (2)
- Turn the power on and press the [▲▼] to set 2 on the program course and press [PRG.]
- Store the programs on L and M processes (Refer to 2-STAGES PROGRAM ABOVE)
- When M chime lamp is illuminated, press [▲▼]to display on -1 and press [OK/PASS]
- Press [▲▼] to set 8 °C/min and press [OK/PASS]
- Press [▲▼] to set 900 °C/min and press [OK/PASS]
- Press [▲▼] to set 1.20 hour and press [OK/PASS]
- Press [▲▼]to display on -2
- Press [PRG.]
Timer
Example: Start the Burnout Course 1 in 8h 30min.
- Turn the power on and press [▲▼] to select 1 on the program course.
- Press [PRESET] and press [▲▼] to program 8.30.
Quick Firing
Choose the programmed course of 2-STAGES or 3-STAGES firing and press [QUICK]. Heat goes up toward the highest temperature programmed in the process at the highest rise speed.
Note: Even in case of quick firing operation, program contents remain unchanged.
Major Error Messages
- Err 6: Thermocouple breakdown
- Err 11: Thermocouple is abnormal or heater breakdown
CONTACT
If you would like to order parts for your machine or have questions,